| PIN |
SIGNAL
NAME |
I/O |
DESCRIPTION |
| 1 |
VANALOG |
OUTPUT |
0-10V analog of output charging voltage waveform (+/- 1%). |
| 3 |
INHIBIT LED |
OUTPUT |
Open collector
output. Indicates the PS is receiving an inhibit input |
| 5 |
EOC
LED |
OUTPUT |
Open collector
output. Indicates the PS has reached end of charge |
| 7 |
INHIBIT |
INPUT |
5 to 15V
inhibits unit operation, Open or Gnd allows operation. Use
this signal to disable charging during HV switch recovery |
| 8 |
ENABLE/RESET |
INPUT |
15V = High
Voltage On, Gnd or open = High Voltage Off |
| 9 |
VPEAK |
OUTPUT |
0-10V Peak
detector of output waveform |
| 10 |
HV
ON LED |
OUTPUT |
Open collector
output. Indicates the HV is ON |
| 12 |
GND |
|
Control
circuit return. Also chassis ground |
| 13 |
IANALOG |
OUTPUT |
Analog of
output waveform (+/-1%) |
| 14 |
+15V |
OUTPUT |
15V through
100ohm series resistor |
| 16 |
OVERTEMP
LED |
OUTPUT |
Open collector
output. Indicates Overtemp fault |
| 17 |
INTERLOCK
LED |
OUTPUT |
Open collector
output. Indicates the interlock is open |
| 18 |
LOAD FAULT
LED |
OUTPUT |
Open collector
output. Indicates output overload, over-voltage, or open
circuit condition |
| 19 |
SUMMARY FAULT LED |
OUTPUT |
Open collector
output. Indicates summary fault |
| 20 |
INHIBIT |
INPUT |
0V inhibits
unit, 15V or open allows operation |
| 22 |
V PROGRAM |
INPUT |
0-10V signal =
0 to 100% of rated voltage |
| 23 |
HV
OFF LED |
OUTPUT |
Open collector
output. Indicates the HV is OFF |
| 24 |
GND |
|
Control
circuit return. Also chassis ground |
| 25 |
+12V
LED |
OUTPUT |
12V at 100mA
max for powering status LEDs |
| PIN |
SIGNAL
NAME |
I/O |
DESCRIPTION |
| 1 |
VANALOG |
OUTPUT |
0-10V analog of output charging voltage waveform (+/- 1%). |
| 3 |
INHIBIT LED |
OUTPUT |
Open collector
output. Indicates the PS is receiving an inhibit input |
| 5 |
EOC
LED |
OUTPUT |
Open collector
output. Indicates the PS has reached end of charge |
| 7 |
INHIBIT |
INPUT |
5 to 15V
inhibits unit operation, Open or Gnd allows operation. Use
this signal to disable charging during HV switch recovery |
| 8 |
ENABLE/RESET |
INPUT |
15V = High
Voltage On, Gnd or open = High Voltage Off |
| 9 |
VPEAK |
OUTPUT |
0-10V Peak
detector of output waveform |
| 10 |
HV
ON LED |
OUTPUT |
Open collector
output. Indicates the HV is ON |
| 12 |
GND |
|
Control
circuit return. Also chassis ground |
| 13 |
IANALOG |
OUTPUT |
Analog of
output waveform (+/-1%) |
| 14 |
+15V |
OUTPUT |
15V through
100ohm series resistor |
| 15 |
TEMP |
OUTPUT |
0-10V signal
indicating the temperature of the main inverter heatsink.
0V=10C 10V=60C |
| 16 |
OVERTEMP
LED |
OUTPUT |
Open collector
output. Indicates Overtemp fault |
| 17 |
INTERLOCK
LED |
OUTPUT |
Open collector
output. Indicates the interlock is open |
| 18 |
LOAD FAULT
LED |
OUTPUT |
Open collector
output. Indicates output overload, over-voltage, or open
circuit condition |
| 19 |
SUMMARY FAULT LED |
OUTPUT |
Open collector
output. Indicates summary fault |
| 20 |
INHIBIT |
INPUT |
0V inhibits
unit, 15V or open allows operation |
| 21 |
PHASE LOSS LED |
OUTPUT |
Open collector
output. Indicates loss of one or more AC input phases |
| 22 |
V PROGRAM |
INPUT |
0-10V signal =
0 to 100% of rated voltage |
| 23 |
HV
OFF LED |
OUTPUT |
Open collector
output. Indicates the HV is OFF |
| 25 |
GND |
|
Control
circuit return. Also chassis ground |
| PIN |
SIGNAL
NAME |
I/O |
DESCRIPTION |
| 1 |
+15V |
OUTPUT |
15V at 125mA max |
| 2 |
SUMMARY FAULT LED |
OUTPUT |
Open collector
output. Indicates a fault condition |
| 3 |
INHIBIT LED |
OUTPUT |
Open collector
output. Indicates the PS is receiving an inhibit input |
| 4 |
EOC
LED |
OUTPUT |
Open collector
output. Indicates the PS has reached end of charge |
| 5 |
EXCESS REVERSAL LED |
OUTPUT |
Open
collector. Senses excess reversal in output circuit. |
| 6 |
COOLANT WARNING LED |
OUTPUT |
Open
collector. Active is the coolant level is low |
| 7 |
OVER VOLTAGE LED |
OUTPUT |
Open
collector. Senses excess voltage at the output. |
| 8 |
ARC LED |
OUTPUT |
Open
collector. Senses arcing in the HV tank. |
| 9 |
AUTO DWELL |
INPUT |
0-10V for
autoinhibit control.
Range 1, 0-10V = 0.5 to 5ms
Range 2, 0-10V = 5 to 50ms |
| 10 |
ENABLE/RESET |
INPUT |
15V = High
Voltage On, Gnd or open = High Voltage Off |
| 11 |
V PROGRAM |
INPUT |
0-10V signal =
0 to 100% of rated voltage |
| 12 |
CURRENT
METER |
OUTPUT |
+10V DC
indicates max current |
| 13 |
VANALOG |
OUTPUT |
0-10V analog of output charging
voltage waveform (+/- 1%). |
| 14 |
INTERLOCK
LED |
OUTPUT |
Open collector
output. Indicates the interlock is open |
| 15 |
INPUT POWER FAULT LED |
OUTPUT |
Open collector
output. Indicates that an input power fault has been detected. |
| 16 |
AUTO DWELL LED |
OUTPUT |
Open collector
output. Indicates auto-dwell is activated |
| 17 |
LOAD FAULT
LED |
OUTPUT |
Open collector
output. Indicates output overload. |
| 18 |
N/C |
|
|
| 19 |
COOLANT FAULT LED |
OUTPUT |
Open collector
output. Indicates internal coolant over temperature or low
coolant level |
| 20 |
PURGE
PUMP LED |
OUTPUT |
Open collector
output. Indicates the internal purge pump is operating |
| 21 |
DIGITAL GND |
|
Common ground
for digital circuits |
| 22 |
INHIBIT |
INPUT |
>3V inhibits
unit, 0V allows operation |
| 23 |
ANALOG
GND |
|
Use for
reference of any analog inputs or outputs |
| 24 |
+11V
DC |
OUTPUT |
Regulated +11V
output for references |
| 25 |
VOLT
METER |
OUTPUT |
+10V DC
indicates max voltage |