Documentation
Data Sheet & Specification
Product Manual
Application Notes
Features

Reduced Package size.
New Patented Inverter 
On-board PFC
Reduced parts count
Remote Controls 
High EMI-RFI Immunity
TUV safety approved (on most models)

Applications

Excimer Lasers
Pulsed YAG Lasers
Lithotriptors
Precipitators
General Low to Medium Power PFN's
Grid Bias Supplies
N2 Lasers
Dye Lasers
TEA Lasers

Other Solutions
Higher Power 102A

App. Notes
APP Note 500: Calculating Capacitor Charge Time
APP Note 502: Calculating AC Line Currents
APP Note 505: Charging units as Continuous Output DC  Supplies
APP Note 507: Charging Large Load Capacitors
APP Note 509: What is Regulation and Repeatability?
APP Note 513: Power Factor Correction
APP Note 517: Protection Against Voltage Reversal
Appn. Questionnaire

 

Page last updated: Tuesday, April 01, 2008

Home


Have a question?
ALE 500A Series. 1-40 kV, 500J/sec

The ALE model 500A is an OEM style High Voltage Power Supply designed for operation in two modes. In the most common format it is a constant current Capacitor Charging Supply which will reliably charge HV capacitors and Pulse Forming Networks (PFN's). The 500A can also operate as a constant voltage, continuous output DC Power Supply with the addition of an external filter capacitor. The entire OEM series supplies employ ALE's patented parallel resonant inverter topology which results in superior pulse to pulse repeatability compared with conventional series resonant designs.


Specification
AC Input
Input Voltage
(VAC)
Current 
(PFC)
Current 
(No PFC)
180-250
47-63Hz
3.5A 5A
90-140V
47-63Hz
7A 10A

Average Charging Rate
500 J/s at rated Output Voltage.

Peak Charging Rate

550 J/s at rated Output Voltage.

Standard Voltage Ranges
1, 1.5, 2, 3, 4, 5, 6, 
10, 15, 20, 30, 40 kV.
All models continuously variable from 0 to 100% of rated voltage output.
Linear to within 1% of full scale. Accuracy 1% of rated.

Polarity
Available as fixed Positive or Negative, Please Specify.

High Voltage Assembly

Voltage Medium Output Cable
1 to 6 kV Air Coax RG58
7 to 40 kV Oil 12AWG, HV Silicon Type DJ

Input Connector
VDE, UL, CSA, approved.

Power Factor

  Non PFC PFC
All Models 0.65 0.98

Efficiency
Better than 85%

Stored Energy
Less than 0.3 Joules all models.

Stability
0.2% per hour after 1 hour warm-up.

Pulse to Pulse Repeatability
+/-
0.2% to 300 Hz. For higher repetition rates, consult factory

Temperature Coefficient
100 PPM per oC
 

Ambient Temperature
Storage: -40 to +85 oC
Operating:-20 to +45 oC

Humidity

90% Non-condensing

Protection
The power supply is protected against open circuits, short circuits, overloads and arcs.

Agency Approvals
Certified to meet  UL 2601.1, EN60601.1 (TUV) Safety requirements.

Note For PFC Units
When high voltage is enabled using either the "HV Enable" Line or de-activation of the "Inhibit" Line, the power supply will reach normal operation mode (and therefore all other published specifications) within 50 milli-seconds.

Mechanical
5.56"(141mm) x 5.75"(146mm) x 14.2"(361mm)
Weight:
Model Non PFC PFC
<6kV 8lbs/3.6kg 10lbs/4.5kg
>6kV 12lbs/5.5kg 14lbs/6.5kg

Click here for mechanical details

Accessories
- Detachable 8 feet HV cable
- 15 pin "D" plug mating control connector
- Operating manual

Remote Control
Via 15pin d-type connector on rear panel. Click here for details

Options

Suffix-LH "Low Inhibit" - A + 10 to 15 volt (high) signal will allow power supply operation. A 0 to +1.5 (low) signal will inhibit the supply.
Suffix-EN "Low Enable" - A + 10 to 15 volt (high) signal will disable power supply operation. A 0 to +1.5 volt (low) signal will enable the supply.
Suffix-5V 0 to +5V programming = 0 to full scale output voltage (standard 0-10V)
Suffix-LP Latching Overload Protection.
Supply will latch off, requiring a reset if an overload condition occurs.

Ordering Information
500A - 15kV - NEG - PFC - LH
Model   Voltage   Polarity   Optional PFC   Options

arrow


© Copyright 1999-2008 Lambda Americas Inc. 
All rights reserved. Legal Information