ALE
402 Resources |
|
Remote
Control Interface
The 402 power supply features a common interface
with the 802 and XR802, via a 25pin D-type female connector located on the rear panel of the unit. The table below
shows details of the function and the pin-out for the connector.
| PIN |
SIGNAL
NAME |
I/O |
DESCRIPTION |
| 1 |
VANALOG |
OUTPUT |
0-10V analog of output charging voltage waveform (+/- 1%). |
| 3 |
INHIBIT LED |
OUTPUT |
Open collector
output. Indicates the PS is receiving an inhibit input |
| 5 |
EOC
LED |
OUTPUT |
Open collector
output. Indicates the PS has reached end of charge |
| 7 |
INHIBIT |
INPUT |
5 to 15V
inhibits unit operation, Open or Gnd allows operation. Use
this signal to disable charging during HV switch recovery |
| 8 |
ENABLE/RESET |
INPUT |
15V = High
Voltage On, Gnd or open = High Voltage Off |
| 9 |
VPEAK |
OUTPUT |
0-10V Peak
detector of output waveform |
| 10 |
HV
ON LED |
OUTPUT |
Open collector
output. Indicates the HV is ON |
| 12 |
GND |
|
Control
circuit return. Also chassis ground |
| 13 |
IANALOG |
OUTPUT |
Analog of
output waveform (+/-1%) |
| 14 |
+15V |
OUTPUT |
15V through
100ohm series resistor |
| 16 |
OVERTEMP
LED |
OUTPUT |
Open collector
output. Indicates Overtemp fault |
| 17 |
INTERLOCK
LED |
OUTPUT |
Open collector
output. Indicates the interlock is open |
| 18 |
LOAD FAULT
LED |
OUTPUT |
Open collector
output. Indicates output overload, over-voltage, or open
circuit condition |
| 19 |
SUMMARY FAULT LED |
OUTPUT |
Open collector
output. Indicates summary fault |
| 20 |
INHIBIT |
INPUT |
0V inhibits
unit, 15V or open allows operation |
| 22 |
V PROGRAM |
INPUT |
0-10V signal =
0 to 100% of rated voltage |
| 23 |
HV
OFF LED |
OUTPUT |
Open collector
output. Indicates the HV is OFF |
| 24 |
GND |
|
Control
circuit return. Also chassis ground |
| 25 |
+12V
LED |
OUTPUT |
12V at 100mA
max for powering status LEDs |
|
|
HV Output
The HV output connector on all oil insulated units is a proprietary
ALE design. A standard 10ft high voltage cable is supplied which is
terminated at the power supply end only. If the supply is operated
at voltages above 20kV and 200Hz rep rate it is recommended that a
silicone grease such as Dow Corning DC-4 is applied to the cable
termination before insertion in the supply. Greasing should be
repeated to ensure as much air as possible is displaced from the
connector.
Mechanical Details
The 402 power supply is packaged in a standard 19" rack mount
chassis with the following external dimensions.
Height: 7" (178mm)
Panel Width:19" (482.6mm)
Chassis Width: 17" (432mm)
Chassis Depth: 17" (432mm)
Click here for a PDF format chassis
drawing
Panel Configurations
The 402 power supply is available with 3 panel configurations the L,
S, and OEM. The L or Lab version features a fully instrumented front
panel with the following functions;
10 turn output voltage
control potentiometer (L only)
Digital average voltage and
current meters (L only)
Digital average voltage and
current bars (L only)
Local/Remote/Off removable
keyswitch (L only)
Power On/Off switch (L/S
only)
View set switch (L only)
HV On/HV Off switches (L
only)
HV ON, HV OFF, INHIBIT, END
OF CHARGE, INTERLOCK OPEN, LOAD FAULT, OVERTEMP indicator LEDs (L/S
only)
The rear panel is equipped with the following
25pin D-type remote
interface connector (female)
25pin D-type slave
interface connector (male) (L only)
BNC INHIBIT Input
Connector (L only)
Interlock terminal strip
(L/S only, optional on OEM)
AC Input terminal strip
HV Output connector
|
|
402 Series ordering details
|
402 |
X-XXkV-XXX-XXX-XX |
|
Package (L/S/OEM)
Rated Voltage (kV)
Polarity (POS/NEG) |
 |
| AC Input Voltage |
Options |
| Omit |
208VAC 3ph |
RS |
Remote load voltage sense |
| 400VAC |
400VAC 3ph + N |
5V |
0 to +5V programming = 0 to full scale output
voltage (standard 0-10V) |
| |
|
LP |
Latching Overload Protection |
| |
|
CT |
AC line contactor (OEM only) |
| |
|
RFI |
Externally mounted RFI filter to reduce
conducted emission |
|
Ordering Example
402L-20kV-POS-400VAC-RS
Model 402 with L front panel, 0-20kV rated output voltage, positive
polarity, 400VAC 3 phase input, remote sense option.


© Copyright 1999-2008 Lambda Americas Inc.
All rights
reserved. Legal
Information
|