AC Input
Input Voltage
(VAC) |
Current
(PFC Only) |
180-250
47-63Hz |
13.5A |
Average Charging Rate
2000 J/s at rated Output Voltage.
Peak Charging Rate
2200 J/s at rated Output Voltage.
Standard Voltage Ranges
1, 1.5, 2, 3, 4, 5, 6,
10, 15, 20, 30, 40 kV.
All models continuously variable from 0 to 100% of rated voltage output.
Linear to within 1% of full scale. Accuracy 1% of rated.
Polarity
Available as fixed Positive or
Negative, Please Specify.
High
Voltage Assembly
| Voltage |
Medium |
Output
Cable |
| 1
to 6 kV |
Air |
Coax
RG58 |
| 7
to 40 kV |
Oil |
12AWG,
HV Silicon Type DJ |
Input
Connector
VDE, UL, CSA, approved.
Power
Factor
| |
Non
PFC |
PFC |
| All
Models |
0.65 |
0.98 |
Efficiency
Better than 85%
Stored
Energy
Less than 0.3 Joules all models.
Stability
0.2% per hour after 1 hour warm-up.
|
Pulse to
Pulse Repeatability
+/-0.2% to 300 Hz. For higher repetition rates,
consult factory
Temperature
Coefficient
100 PPM per oC
Ambient
Temperature
Storage: -40 to +85 oC
Operating:-20 to +45 oC
Humidity
90% Non-condensing
Protection
The power supply is protected against open
circuits, short circuits, overloads and arcs.
Agency
Approvals
Designed to meet UL 2601.1, EN60601.1 (TUV) Safety
requirements.
Note
For PFC Units
When high voltage is enabled using either
the "HV Enable" Line or de-activation of the
"Inhibit" Line, the power supply will reach
normal operation mode (and therefore all other published
specifications) within 50 milli-seconds.
Mechanical
5.56"(141mm) x 5.75"(146mm) x 14.5"(368mm)
Weight: 20lbs (9kg)
Click here for mechanical details
Accessories
- Detachable 8 feet HV cable
- 15 pin "D" plug mating control connector
- Operating manual
Remote Control
Via 15pin d-type connector on rear panel. Click
here for details
Options
| Suffix-LH |
"Low
Inhibit" - A + 10 to 15 volt (high) signal
will allow power supply operation. A 0 to +1.5 (low)
signal will inhibit the supply. |
| Suffix-EN |
"Low
Enable" - A + 10 to 15 volt (high) signal
will disable power supply operation. A 0 to +1.5
volt (low) signal will enable the supply. |
| Suffix-5V |
0 to +5V programming = 0 to full scale output
voltage (standard 0-10V) |
| Suffix-LP |
Latching Overload Protection.
Supply will latch off, requiring a reset if an overload
condition occurs. |
|